C-Tec FF392-2

C-TEC’s FP Range of conventional fire alarm control panels is one of the most robust and cost-effective available.

Fully compliant with BS 5839 part 4, the range encompasses no less than ten different variants, covering 1 to 14 zones.

The size, durability and flexibility of the range makes it ideal for use in all types of commercial and residential property including small shops, factories, schools, warehouses, offices and houses in multiple occupation.

Often referred to as ‘the installer’s choice’, easy-to-follow wiring instructions are printed adjacent to the terminals of all variants and a lift-off lid guarantees an easy first fix and straightforward maintenance.

The panel’s broad compatibility with virtually all known smoke and heat detector ranges and its ability to interpret a short circuit in any zone(s) as a fire or fault condition make it particularly useful for retro-installations.

An optional head removal facility (which utilises C-TEC’s BF378 range of end-of-line monitoring units) is also available, making the FP fully compliant with the head removal requirements of BS 5839 part 1.

FP Range Features

  • Fully compliant with BS 5839 Part 4
  • Lift-off lid for easy first fix and maintenance
  • Attractive easy-to-clean polycarbonate front label
  • Heavy-duty base connections
  • Robust metal lid and metal back box
  • Ultra-bright, long-life LED indicators
  • Built-in 24V power supply and battery charger
  • Optional head removal facility for compliance with BS 5839 Part 1
  • Compatibility with virtually all known conventional smoke and heat detector ranges
  • True three wire operation of sounder and detector circuits (Ov is common) for considerable cost savings on installation
  • Separate indicators for open and short circuit fault, sounder fault and battery/power supply fault
  • Non-latching ‘class change’ sounder input, latching fire and non-latching fault outputs (available via optional expansion loom)
  • Fault buzzer mute facility
  • Space available for the rated capacity of VRLA batteries
  • Short circuit = fire facility (pre-1980 BS, no resistors in call points), selectable on a zone by zone basis for retro-installations
  • True battery monitoring circuit
  • One man walk test and zone isolate facility (not available on EFP1)
  • Ancillary connections for repeater panels and other system add- including fault relay modules, fire relay modules, sounder delay relay modules, sounder extender kits, etc (not available on EFP1)
  • Easy to follow installation instructions and log book
  • Multilingual variants available (subject to quantities)
Power Supply SpecificationEFP1FP2, FP2EFP4, FP6, FP8EFP8, FP10, FP12, FP14
Mains supply voltage 230V a.c ± 10% 50/60 Hz 230V a.c. ± 10% 50/60 Hz 230V a.c. ± 10% 50/60 Hz 230V a.c. ± 10% 50/60 Hz
Internal power supply 27V d.c. nominal 27V d.c nominal 27V d.c nominal 27V d.c nominal
Total output current limited to 400mA @ 230 V a.c. 800mA @ 230 V a.c. 1.4A @ 230 V a.c. 3A @ 230 V a.c.
Supply and battery charger monitored for failure Yes Yes Yes Yes
Batteries monitored for disconnection and failure Yes Yes Yes Yes
Detector Circuit Specification
Number of circuits 1 (EFP1, non-extendable) 2 (FP2, non-extendable)
4 (FP4E, non-extendable)
4 (FP4, extendable to 6)
6 (FP6, non-extendable)
8 (FP8E, non-extendable)
8 (FP8, extendable to 14)
10 (FP10, extendable to 14)
12 (FP12, extendable to 14)
14 (FP14, non-extendable)
Connector blocks
Heavy duty Niglon-type, largest acceptable conductor size 2.5mm2
Line monitored for open and short circuit faults Yes Yes Yes Yes
Line monitored for head out/detector removed faults Yes - if optional BF378 or BF378M End of Line Monitoring unit (not supplied) is fitted in place of end of line resistor
End of line resistor value (supplied) 6800 Ω 5% Tol. 0.25W 6800 Ω 5% Tol. 0.25 W 6800 Ω 5% Tol. 0.25 W 6800 Ω 5% Tol. 0.25 W
Detector continuity diodes Silicon 1N4001 or Schottky type (required if BF378 or BF378M End of Line Monitoring Unit is fitted to show head out faults)
Call point resistor value (not supplied) 470 - 680 Ω 0.5 W 470 - 680 Ω 0.5 W 470 - 680 Ω 0.5 W 470 - 680 Ω 0.5 W
Max. number of detectors per zone 20 (max detector current 2mA) 20 (max detector current 2mA) 20 (max detector current 2mA) 20 (max detector current 2mA)
Max. number of manual call points per zone No limit No limit No limit No limit
fp technical specifications fp technical specifications Battery Stand-By Times Sounder Circuit Specification
Number of circuits 2 2 2 2
Connector blocks Heavy duty Niglon-type, largest acceptable conductor size 2.5mm²
End of line resistor value 6800 Ω 5% Tol. 0.25 W 6800 Ω 5% Tol. 0.25 W 6800 Ω 5% Tol. 0.25 W 6800 Ω 5% Tol. 0.25 W
Line monitored for open and short circuit faults Yes Yes Yes Yes
Outputs fused at 400mA 1A 1A 1.6A
Max. total output current to all outputs 400mA 800mA 1.4A 3A
Max. number of bells at 25mA 16 32 56 120
Max. number of sounders at 20mA 20 40 70 150
Volt free relay contacts (active when sounders active) n/a Yes, 1A 30V d.c. max Yes, 1A 30V d.c. max Yes, 1A 30V d.c. max

Dimensions

Approx. dimensions of enclosure (W x H x D) 271 x 200 x 70mm 322 x 267 x 92mm 405 x 267 x 92mm 521 x 334 x 140mm
Weight (without batteries) 2.3kg 4.3kg 5.0kg 9.2 kg

Auxiliary Inputs / Outputs

Available via optional expansion looms (not supplied) Class change input,
fire output and fault
output via EFPX loom
Class change input, zone 1 & zone 2 fire outputs, fault output and reset output
via FPX loom. Self-contained fire, fault & sounder delay relay modules
are also available (1 per panel instead of FPX loom)

Repeater Specification

Max. number of repeaters n/a Three repeaters per main panel. Repeaters are available with 10 or 20 zones.
Repeater wiring n/a Five control wires plus one extra wire per zone being repeated;
max cable length 200m

Fuses (to IEC - EN60127 Pt2)

Mains terminal block 125mA T 20mm 200mA T 20mm 400mA T 20mm 630mA T 20mm
Sounder outputs 400mA F 20mm (F1, F2) 1A F 20mm (F2, F3) 1A F 20mm (F2, F3) 1.6A F 20mm (F2, F3)
Auxiliary output n/a 1A F 20mm (F4) 1A F 20mm (F4) 1A F 20mm (F4)
Battery fuse 1A F 20mm (F3) 1.6A F 20mm (F1) 1.6A F 20mm (F1) 3A F 20mm (F1)

Panel Indicators and Controls

External indicators Mains On; Zone Fire; Zone Fault; Sounder Fault; Battery/Power Supply Fault
Internal Indicators O/C Fault; S/C Fault O/C Fault; S/C Fault;Zone Isolated; Engineer Test Selected
External controls (keyswitch operated) Reset; Silence Alarm/Fault
Sounders; Evacuate;
Reset/ Resound/Test Zone Lamps; Evacuate; Silence Alarm Sounders;
Silence Fault Sounders
Internal controls Revert to short circuit = fire Revert to short circuit = fire; One man detector test; Zone isolate;

Battery Standby Times


EFP1 FP2 FP4E FP4 FP6 FP8E FP8 FP10 FP12 FP14
Quiescent current 25mA 40mA 50mA 50mA 60mA 70mA 70mA 80mA 90mA 100mA
Max. load current 0.4A 0.8A 0.8A 1.4A 1.4A 1.4A 3.0A 3.0A 3.0A 3.0A
Stand-by time in hours using 1.2 Ahr batteries 48 - - - - - - - - -
Stand-by time in hours using 2.0 Ahr batteries 80 40 32 26 - - - - - -
Stand-by time in hours using 2.6 Ahr batteries - 55 44 38 32 27 - - - -
Stand-by time in hours using 4.0 Ahr batteries - 90 72 66 55 47 36 31 28 25
Stand-by time in hours using 6.0 Ahr batteries - - - 106 88 75 64 56 50 45
Stand-by time in hours using 10.0 Ahr batteries - - - - - - 121 106 94 85
The quiescent current given is for the following conditions - mains supply failed, fault beeper muted, no aux. output connections, detector and sounder end of line devices fitted, no other loads supplied by the panel. The battery stand-by times are guidelines only based on the above conditions and a full sounder load for 30 minutes. Additional loads that increase the quiescent current in the normal state must be considered when calculating stand-by time. The fault beeper being active will add 10mA and reduced sounder loads will increase the stand-by time. Batteries in poor condition greatly reduce stand-by time.

FP Range Panels

FF380-2 EFP1 single zone fire panel, does not extend
FF382-2 FP2 zone fire panel, does not extend
FF384-3 FP4 zone economy fire panel, does not extend
FF384-2 FP4 zone fire panel, extends to 6 zones
FF386-2 FP6 zone fire panel, does not extend
FF388-3 FP8 zone economy fire panel, does not extend
FF388-2 FP8 zone fire panel, extends to 14 zones
FF390-2 FP10 zone fire panel, extends to 14 zones
FF392-2 FP12 zone fire panel, extends to 14 zones
FF394-2 FP14 zone fire panel, does not extend
FF387Z-2 FP2 zone extender PCB kit
(use to increase number of zones on FP panels)
FF396-2 FP10 zone repeater panel
FF398-2 FP 20 zone repeater panel

FP Range Ancillaries

FF374X FPX expansion loom (not compatible with EFP1)
FF374FR FP fault relay module (not compatible with EFP1)
FF374DFR FP fire relay module (not compatible with EFP1)
FF374DT FP sounder delay module (not compatible with EFP1)
FF380X EFPX expansion loom (for use with EFP1 only)
BF378 EMU end of line ‘head out’ monitoring unit
BF378M MIMIMU miniature end of line ‘head out’ monitoring unit
BF379 Schottky diodes, 10 pack (BYV1060/SR160)
FF502P Four zone sounder extender kit
FF379 Flush bezel for use with FP2 and FP4E panels
FF385 Flush bezel for use with FP4, FP6, FP8E and FP repeater panels
FF387 Flush bezel for use with FP8, FP10, FP12 and FP14 panels
Note: The EFP1 is designed to be surface mounted only

Battery Packs

BC283/2 24V 1.2 AmpHr battery pack
BC284/2 24V 2.1 AmpHr battery pack
BC285/2 24V 2.8 AmpHr battery pack
BC286/2 24V 7.0 AmpHr battery pack